Failure repair procedure for elevator parts

Your current position: Home >> News >> Technical knowledge

Failure repair procedure for elevator parts

Release date:2016-09-09 00:00 Source:http://www.top-elevator.cn Clicks:

1 Purpose

To ensure that the elevator in the event of failure to get reliable and correct maintenance and treatment, the ultimate guarantee of the elevator components to the normal use.

2 scope of application

Elevator fault handling under the jurisdiction of the administrative office.

3 responsibilities

3.1 elevator maintenance unit is responsible for the implementation of procedures for reference, and fill out the "elevator maintenance record".

3.2 government office responsible for completing the "lift elevator maintenance record" and notify the elevator maintenance unit troubleshooting.

4 content

4.1 elevator failure rate should be arrived at the scene (and the attendant to lift the subcontractors for five minutes; twenty minutes).

4.2 in the elevator maintenance work, should be the host safety technical disclosure.

4.3 first understand the failure phenomenon, analysis of the causes of failure, analysis of the location of the fault.

4.4 elevator fault is generally divided into two types of mechanical failure and electrical failure.

5 common mechanical failures

5.1 room

5.1.1 motor bearing fault. Abnormal sound of the motor operation, such as the determination of the bearing fault, remove the motor check bearings, such as issuing, wear is too large, must replace the bearing.

5.1.2 layer selection device failure generally have the following:

5.1.3 brake fault: there are friction phenomenon between the brake shoe and the brake wheel adjustment, brake shoe, brake shoe oil, replace the brake shoes, in addition to the wheel brake oil.

5.1.4 overspeed fault: rope and rope groove jaw with debris, bearing damage, debris removal, replacement of bearings.

5.2 well way and car:

5.2.1 car door and automatic door mechanism of failure: when opening and closing the door shaking sound, do not open the door, open the door is not closed, sound, touch the door gap is too large, clear sill chute debris, adjusting the spacing wheel, replace the damaged door hanging wheel, adjusting gate gap, adjusting the contact plate and a connecting rod turn the gas etc..

5.2.2 hall door failure.

5.2.3 open the door knife fault: run when there is touch or suddenly stop, adjust the door knife position (open the door and the door of the hall gap, open the door and the door of the door hang round clearance).

5.2.4 rail fault: unstable operation, shaking and vibration phenomenon, adjust track size, for road foot adjustment, track Hsiuping interface file.

5.2.5 boot failure: unstable operation, iron sound, vibration, wear, replace the guide shoe piece, guide shoe seat position is not adjusted.

5.2.6 security: FileReader iron clamp fault sound, serious safety action will brake or unilateral brake; adjust the safety clamp clearance, safety linkage, lubrication, ensure each moving part flexible.

5.3 bottom pit:

5.3.1 compensation chain fault: run when there is touch chain sound, due to the compensation growth or shorten and other reasons, adjust the compensation chain.

5.3.2 safety pliers wire rope tension wheel failure: the operation of the wire rope or the sound of the abnormal sound; adjust the safety clamp wire rope, replace the bearing.

Fault: 5.3.3 buffer buffer rust, no activity, lack of hydraulic oil; in addition to rust, add the hydraulic oil

6 elevator general common electrical fault

6.1 room

6.1.1 fuse failure: buffer pit stop, broken rope switch short-circuit reason system, discharging pit water, eliminate the short point, put on the same fuse, door door security loop, wells due to water, a short circuit fault caused by water exchanges, eliminate the short fuse, change on the same indicator circuit, because the hall indicates water or cable rupture due to short circuit. Dry water, eliminate the short circuit point, replace the fuse, control loop because the control coil is burned, the control element internal short circuit, replace the control coil and control elements, exclude line short circuit point, put on the same fuse.

6.1.2 contactor and circuit breaker fault: contactor or relay does not work, because the contactor or relay coil burnout, control circuit or disconnect plug-in, the control circuit is caused by burn insurance and other reasons, the replacement of the contactor or relay, exclude the breaking point, replacing the fuse.

6.2 well way and car:

6.2.1 upper and lower limit and limit switch fault: the elevator guide rail this failure of the elevator can not take the car, generally due to switch contact is not good or open circuit and other reasons, cleaning contact point or replace, remove the breakpoint, etc..

6.2.2 car door, door interlock switch failure: this failure is not only close to the elevator car door, generally due to the interlocking switch contact is not good or switch damage, circuit breakers and other reasons. Clean the contact point, replace the switch to exclude line break point, etc..

6.2.3 safety clamp switch, safety window switch, car top emergency stop: the failure of the elevator does not take the car, generally due to poor contact or damage caused by the switch. Clean the contact point, replace the switch.

6.3 bottom pit:

6.3.1 buffer switch and pit stop switch: the failure of the elevator does not go in the car, usually due to poor contact, the buffer reset is not in place, the main wire rope is too long, the damage caused by heavy hit buffer switch; clean contacts, buffer reduction, shortened main wire rope replacement switch.

6.3.2 tensioner rope switch fault: the fault elevator does not go in the car, usually due to bad contact switch, safety switch wire clamp is too long, caused by damage, clean the contact point, shorten the safety wire clamp, replace the switch.

7 note

7.1 elevator maintenance must comply with the "Regulations" and "safety production system of elevator maintenance safety".

The above is a common failure of the processing, special, difficult to be done by a professional company to do more testing, testing, and then determine the maintenance program, and to implement.


Relate tags:elevatorparts

Recent browse:

Suzhou Top Elevator Parts Co.,Ltd 

National Service Hotline:0086-512-58731058

Tel:0086-512-58731058 

Fax:0086-512-58731108

mail:sue@topelevator.cn

Add:Zhujiadang Village Houcheng Jingang Town Zhangjiagang City Jiangsu Province China

web:www.top-elevator.cn      www.topelevator.cn

Share
Welcome to us message
Please enter the message content, we will contact you soon.
Name
contacts
Tel
telephone number
Email
Email